Sofia Vicquery
Optimization of PEO coatings on magnesium alloys: towards a balance between biocompatible materials and durability for biomedical implants.
Rel. Sara Ferraris. Politecnico di Torino, Corso di laurea magistrale in Ingegneria Dei Materiali Per L'Industria 4.0, 2026
|
Preview |
PDF (Tesi_di_laurea)
- Tesi
Licenza: Creative Commons Attribution Non-commercial No Derivatives. Download (5MB) | Preview |
Abstract
Magnesium alloys are increasingly investigated for biodegradable biomedical implants due to their mechanical properties and biocompatibility. However, their high corrosion rate in physiological environments still represents a major limitation. In this work, AZ31 magnesium alloy was treated by Plasma Electrolytic Oxidation (PEO) followed by a phosphate post-conversion treatment to improve corrosion resistance and promote the incorporation of the anti-inflammatory drug Betamethasone Sodium Phosphate (BSP). The phosphate conversion treatment was performed in a Na–P solution at pH 9 and 60 °C, investigating three immersion times (30 min, 1 h and 2 h). Morphological, chemical and electrochemical characterizations were carried out through SEM-EDS, XRD and Electrochemical Impedance Spectroscopy (EIS).
The results showed that the 1 h treatment provided the most favourable balance between phosphate layer formation and preservation of the underlying PEO coating
Relatori
Anno Accademico
Tipo di pubblicazione
Numero di pagine
Corso di laurea
Classe di laurea
Ente in cotutela
Aziende collaboratrici
URI
![]() |
Modifica (riservato agli operatori) |